Edited by Huanghe Cable Technical Team · Updated: October 2026 · Reading time: 12–14 minutes
Looking for an armoured cable manufacturer in China for an industrial, infrastructure, or power distribution project? Sourcing a reliable metal-armoured cable is critical for harsh underground, outdoor, and heavy-duty environments. This technical guide sets out our LV and MV armoured cable range, the international standards we manufacture to, special sheath options, and how to submit a complete RFQ that returns a comparable quotation.
Established in 1980 and backed by more than 45 years of manufacturing expertise, Huanghe Cable supplies high-performance LV and MV armoured power cables to EPC contractors, utilities, distributors, and industrial buyers worldwide.
Our core manufacturing range covers low-voltage (LV) armoured power cables from 1.5–800 mm² (routinely manufactured and tested to IEC 60502-1 or BS 5467), medium-voltage (MV) single-core cables from 35–630 mm², and MV three-core cables from 35–500 mm² (manufactured to IEC 60502-2), featuring SWA, STA, or non-magnetic AWA configurations. For European and German-style series, XLPE-insulated low-voltage constructions such as N2XBY / N2XRY comply with DIN VDE 0276-604 (HD 604), NYY / NAYY follow DIN VDE 0276-603, and MV series such as N2XSY / NA2XSY follow DIN VDE 0276-620.
Beyond standard sizes, we support tailored project requirements including flame-retardant and Low Smoke Zero Halogen (LSZH) sheaths, anti-termite additives, Factory Acceptance Testing (FAT), and third-party inspection.
Key Takeaways
Contents
The right armoured cable should match the project’s electrical requirements, installation conditions, mechanical protection needs, and applicable standard.
Direct Answer
An armoured cable manufacturer supplies power cables with a metallic armour layer — steel wire armour (SWA), steel tape armour (STA), or aluminium wire armour (AWA) — for mechanical protection in underground, outdoor, and heavy-duty installations. Huanghe Cable manufactures LV armoured cable from 1.5–800 mm² to IEC 60502-1 and MV armoured cable from 35–630 mm² to IEC 60502-2, in copper or aluminium, and reviews the cable schedule or BOQ before production.
Armoured power cables are used in installations where the specified construction includes an additional metallic protection layer. The suitable design depends on the voltage rating, conductor material, number of cores, insulation system, armour type, outer sheath, and installation method.
Huanghe Cable works with contractors, EPC companies, distributors, utilities, and industrial buyers to review cable specifications before production. Buyers can submit a cable schedule, bill of quantities (BOQ), datasheet, or project specification for review.
For product details, visit our Armoured Power Cable product page.
Have a cable schedule or project specification?
The following table summarizes the principal cable size ranges and product categories available from Huanghe Cable. Final availability depends on the requested model, construction, voltage rating, and applicable standard.
| Cable Category | Core Arrangement and Size | Voltage Range | Typical Construction |
|---|---|---|---|
| LV Armoured Power Cable | 1–5 cores; 2+1, 3+1, 3+2, 4+1 cores; 1.5–800 mm² | 0.6/1 kV, 1.8/3 kV | XLPE or PVC insulation; steel tape or steel wire armour where specified |
| MV Single-Core Cable | 1 core; 35–630 mm² | 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 18/30 kV, 26/35 kV | XLPE insulation, metallic screen, and suitable armour construction |
| MV Three-Core Cable | 3 cores; 35–500 mm² | 3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 18/30 kV, 26/35 kV | XLPE insulation, metallic screening, and specified armour |
| Special Sheath Options | Project-specific configuration | According to the cable design | Options may include LSZH, flame-retardant, and anti-termite sheath constructions |
Note: The stated size ranges describe the principal LV and MV supply ranges. For special high-capacity power distribution or substation projects requiring conductor cross-sections above 630 mm² (Single-core) or 500 mm² (Three-core), technical feasibility and custom manufacturing can be evaluated upon receiving the specific system short-circuit capacity requirements. Please provide the complete specification for confirmation.
The following Chinese model designations are commonly used when specifying LV and MV power cables. The exact construction should be confirmed against the applicable product datasheet.
| Model | Typical Construction | Procurement Notes |
|---|---|---|
| YJV22 / YJLV22 | XLPE insulation with double steel tape armour (DSTA) and PVC/PE sheath options, according to the specified model | Confirm conductor material, voltage rating, core count, and sheath |
| YJV32 / YJLV32 | XLPE insulation with steel wire armour (SWA) and specified outer sheath | Confirm installation requirements and cable construction |
| VV22 / VLV22 | PVC insulation with steel tape armour and PVC sheath | Confirm copper or aluminium conductor and required size |
| YJV62 | Non-magnetic metallic tape armour | Confirm the complete construction and electrical application |
| YJV72 | Non-magnetic metallic wire armour | Confirm the complete construction and electrical application |
| YJLY23 | Aluminium conductor, XLPE insulation, steel tape armour, PE outer sheath | Confirm conductor size, voltage rating, and PE sheath requirement |
Huanghe Cable can supply product series using common German-style cable designations, including NYY, NAYY, N2XY, NA2XY, N2XBY, NA2XBY, N2XRY, NA2XRY, N2XSY, NA2XSY, and N2XSEY. These designations appear in cable schedules, tender documents, and industrial power project specifications.
German-style designations describe aspects of cable construction, but the exact structure and compliance requirements must be read together with the referenced DIN/VDE standard and the project specification. A German-style model name should not automatically be treated as a one-to-one equivalent of a Chinese model.
| German-Style Designation | Typical Cable Description | What to Confirm in the RFQ |
|---|---|---|
| NYY / NAYY | PVC-insulated, PVC-sheathed LV power cable; NAYY denotes an aluminium-conductor version | Conductor material, core arrangement, rated voltage, and required standard. |
| N2XY / NA2XY | XLPE-insulated, PVC-sheathed LV power cable; NA2XY denotes an aluminium-conductor version | Conductor size, core count, voltage rating, and whether additional armour is specified. |
| N2XBY / NA2XBY | Common designation associated with XLPE-insulated cable with steel tape armour (STA) and PVC sheath | Confirm whether the steel tape is galvanised and check the exact bedding and outer sheath thickness under DIN VDE 0276-604. |
| N2XRY / NA2XRY | Common designation associated with XLPE-insulated cable with steel wire armour (SWA) and PVC sheath | Confirm whether the steel wire is galvanised and check the exact bedding and outer sheath thickness under DIN VDE 0276-604. |
| N2XSY / NA2XSY | MV cable designation associated with XLPE insulation, screening, and PVC sheath; NA2XSY denotes an aluminium-conductor variant | Rated voltage, screen construction, conductor size, and applicable standard. |
| N2XSEY | German-style MV cable designation associated with screened XLPE-insulated construction | Conductor, screen, core arrangement, sheath, voltage, and standard. |
Supply note: Huanghe Cable can supply the German-designation cable series listed above. When submitting an RFQ for N2XBY / NA2XBY or N2XRY / NA2XRY, please reference the applicable DIN VDE 0276-604 (or project-specific edition) alongside the voltage, conductor, and sheath requirements. For N2XSY / NA2XSY MV series, DIN VDE 0276-620 is commonly referenced. Providing the exact standard edition allows us to verify the bedding thickness, armour galvanisation, and routine test parameters against your specification.
A cable enquiry should identify more than the general term “armoured cable.” A complete specification states the construction, the standard, the quantity, and the destination.
Example LV cable specification:
0.6/1 kV, copper conductor, XLPE insulation, 4-core × 70 mm², steel tape armour, PVC outer sheath, required standard, total length, and delivery destination.
Example MV cable specification:
8.7/15 kV, aluminium conductor, XLPE insulation, 3-core × 185 mm², copper wire screen, steel tape armour, PE outer sheath, IEC 60502-2, total length, and delivery destination.
This is an illustrative RFQ format, not a statement that every combination is available in every model. For MV cables, state the voltage designation, single-core or three-core arrangement, conductor cross-section, metallic screen construction, armour type, outer sheath, applicable standard, quantity, and destination.
Steel wire armour (SWA), steel tape armour (STA), and aluminium wire armour (AWA) are different construction options. The comparison below shows how they differ in practice; the final selection should be based on the approved cable design and the installation requirements.
| Armour Type | Construction | Selection Considerations |
|---|---|---|
| SWA | Steel wire armour | Mechanical protection and any required tensile performance must be assessed against the cable design and installation method. |
| STA | Steel tape armour | Commonly specified for certain cable constructions; installation method and bending radius must follow the datasheet. |
| AWA | Aluminium wire armour | A non-magnetic armour option for suitable single-core AC cable designs where magnetic effects must be considered. |
For single-core AC circuits, a non-magnetic armour such as aluminium wire armour (AWA) should be used instead of steel armour. A ferromagnetic armour on a single-core AC cable would carry induced circulating currents and generate eddy-current heating, so the armour material must be confirmed at the design stage. In Chinese model coding, this non-magnetic wire armour construction is typically designated within the YJV72 / YJLV72 series. Always confirm the specific armour material (aluminium or non-magnetic stainless steel) and the applicable standard in your RFQ.
For further information about model codes, see How to Read Power Cable Codes: YJV, YJV22, YJV32 and N2XY Explained.

Steel tape and steel wire armoured power cable constructions.
Armour is specified when the cable route needs additional mechanical protection. The table below summarises the environments most often reviewed for LV and MV armoured cable projects, together with the details that should accompany the enquiry.
| Installation Environment | Typical Armour Consideration | Details to Confirm in the RFQ |
|---|---|---|
| Direct burial in soil | Steel tape or steel wire armour for mechanical protection; anti-termite sheath option in termite-prone regions | Burial depth, soil thermal resistivity, backfill and protection arrangement, ambient temperature |
| Cable ducts and conduits | Armour selected against pulling tension and site handling | Duct diameter, number of bends, pulling length, and any maximum pulling tension |
| Cable trays and racks in industrial plants | Steel tape armour for multicore cable; non-magnetic armour for single-core AC cable | Grouping and derating factor, tray material, and any fire-performance requirement |
| Outdoor and exposed routes | UV-resistant PVC or PE outer sheath with the specified armour | UV exposure, wind loading, support spacing, and required sheath material |
| Substations and distribution rooms | MV metallic screen plus the specified armour construction | Rated voltage, short-circuit rating and duration, screen cross-section |
| Vertical shafts and risers | Steel wire armour where tensile loading during installation must be considered | Vertical drop, support intervals, and permissible pulling tension |
The same conductor size may need a different construction depending on the route. If the installation combines several environments — for example direct burial for part of the run and a cable tray for the remainder — describe the full route in the enquiry so that the armour, sheath, and current rating can be reviewed together.
Projects may require specific cable designs rather than a standard catalogue configuration. Huanghe Cable can review the requested construction and manufacturing scope using the project specification or cable schedule.
Any proposed alternative to a project specification should be reviewed and approved before production. A change in conductor material, insulation, armour, or sheath may affect the cable’s electrical, mechanical, and compliance requirements.
Have an existing cable specification?
Send your cable schedule, BOQ, datasheet, drawing, or model designation. Our team can review the requested construction and identify any technical details that need clarification.
Product compliance and inspection documentation should relate to the actual cable model and the requirements agreed for the order.
For an international power cable project, buyers should identify the applicable product standard, technical requirements, and inspection scope before production. A general statement about a manufacturer’s capabilities does not replace confirmation of the standard and documents applicable to the ordered cable.
Depending on the project and contract, documentation and inspection arrangements may include:
Finished cable is routine-tested before shipment, including spark testing of the insulation and partial discharge testing where applicable to the agreed design. The specific routine test list and any additional contractual tests are agreed for each order.
Learn more about Huanghe Cable. Applicable standards, product documents, inspection scope, and any required third-party verification should be agreed for the specific product and order.
Where third-party inspection is required, the inspection scope, sampling plan, test requirements, and reporting arrangements should be agreed before production or shipment. This helps both parties understand which checks will be performed and which documents will be supplied.

Huanghe LV & MV armoured power cables exported to South Africa, Philippines, Kazakhstan etc.
Huanghe Cable was founded in 1980 and has manufactured power and industrial cable products for more than 45 years. Our quality management system is certified to ISO 9001, and our LV and MV power cables are manufactured to IEC requirements. We supply armoured cable to projects and distributors across Southeast Asia, Central Asia, the Middle East and Africa.
For armoured cable projects, buyers can discuss the required voltage rating, conductor, insulation, armour, sheath, applicable standards, quantity, and inspection requirements with our team.
A project enquiry can include:
Huanghe Cable’s wider product range includes XLPE and PVC power cables, control cables, rubber cables, photovoltaic cables, overhead conductors, and building wires. For projects requiring several cable categories, include the products in the same enquiry so the scope can be reviewed together.
Explore our XLPE Power Cables page for more product information.
Send your cable schedule or target specification, including voltage, cores, cross-sectional area, armour type, and quantity. Huanghe Cable aims to provide a technical response and quotation within 12 hours.
Email: sales@huanghecables.com
To help us review your requirements efficiently, include as much of the following information as is currently available.
| Information | What to Provide |
|---|---|
| Cable type | Product designation, datasheet, drawing, or cable schedule. |
| Electrical specification | Voltage rating, conductor material and size, core count, and required standard. |
| Cable construction | Insulation, screen, armour, sheath, and other specified requirements. |
| Quantity and packaging | Total cable length, preferred drum lengths, and packaging instructions. |
| Target timeline | Required delivery date or project phase. Typical production lead time for standard LV armoured cable is 5–15 days after drawing approval; MV and special sheath options may require longer. |
| Delivery and inspection | Destination country or port, requested delivery schedule, and inspection or documentation requirements. |
If some information is not yet available, you can still submit the documents you have. Our team can identify the details that need clarification. Final pricing and delivery arrangements depend on the confirmed specification, quantity, production requirements, and destination.
For more guidance, read How to Write a Power Cable RFQ: Technical Details Suppliers Need Before Quoting.
An armoured cable quotation is built from the confirmed construction, not from the model name alone. Two cables both described as a “4-core 70 mm² armoured cable” can differ in conductor material, armour type, sheath, standard, and testing scope — and the prices will not be comparable.
| Cost Factor | Why It Changes the Price |
|---|---|
| Conductor material and size | Copper and aluminium have different raw-material costs, and conductor weight is usually the largest single cost element in the cable. |
| Voltage rating and insulation design | MV insulation thickness, conductor screen, and insulation screen add material and processing steps compared with LV construction. |
| Armour type | Steel wire armour, steel tape armour, and non-magnetic AWA require different materials and different manufacturing time. |
| Outer sheath | PVC, PE, LSZH, flame-retardant, and anti-termite compounds carry different material costs. |
| Standard and testing scope | Routine testing is standard; FAT, additional tests, and third-party inspection add cost and lead time. |
| Quantity and drum length | Larger order quantities improve material utilisation, while non-standard drum lengths may increase waste. |
| Destination and packaging | Drum type, packing, inland transport, and the agreed shipping terms affect the delivered price. |
To receive a comparable quotation, send the complete specification listed in the RFQ table above. We confirm the technical basis before quoting, so that the price reflects the cable the project actually requires.
An armoured cable manufacturer supplies cables with a specified metallic armour construction, conductor, insulation, and sheath. Product ranges may include LV and MV power cables, depending on the manufacturer’s capabilities and the agreed specification.
An armoured cable includes a metallic armour layer that provides additional mechanical protection, so it is used where the route involves direct burial, site handling, or other mechanical risk. An unarmoured cable has no armour layer and is generally specified for protected routes such as indoor trays, ducts, and cabinets where mechanical protection is provided by the installation.
SWA uses steel wires as the armour layer, while steel tape armoured cable uses steel tape. Steel wire armour is generally considered where higher tensile strength during installation or operation is required; steel tape armour is commonly specified where mechanical protection is the main requirement. The appropriate construction depends on the cable design, electrical system, installation method, and project specification.
Huanghe Cable supplies copper and aluminium conductor cable options across its product range. The available conductor material, size, core count, and construction should be confirmed for the requested model and voltage rating.
The principal LV armoured cable size range is 1.5–800 mm². For MV cables, the range is 35–630 mm² for single-core cables and 35–500 mm² for three-core cables. The exact voltage and construction combination should be confirmed against the project specification.
Yes. Huanghe Cable can supply product series using German-style designations including NYY, NAYY, N2XY, NA2XY, N2XBY, NA2XBY, N2XRY, NA2XRY, N2XSY, NA2XSY, and N2XSEY. Send the required DIN/VDE standard, datasheet, cable schedule, BOQ, or drawing so the requested construction and technical requirements can be reviewed.
Armoured cable is commonly specified for direct burial because the metallic armour provides mechanical protection against the installation and service conditions. The burial depth, soil thermal resistivity, backfill arrangement, and any local requirements should be stated in the enquiry so that the armour, sheath, and current rating can be reviewed together.
The main factors are conductor material and size, voltage rating and insulation design, armour type, outer sheath material, the applicable standard and testing scope, order quantity and drum length, and the delivery destination. Because the quotation follows the confirmed construction, a complete specification is the fastest route to a comparable price.
Factory acceptance testing (FAT) and third-party inspection can be discussed according to the project specification and agreed order scope. Inspection requirements, test procedures, acceptance criteria, and documentation should be agreed before production or shipment.
Submit the cable model, voltage rating, conductor details, size, core count, construction, quantity, and delivery destination through the website enquiry form or by emailing sales@huanghecables.com. You can also contact Huanghe Cable on Viber/WhatsApp at +86 15136256310.

Armoured power cable manufacturing and shipping.
Armoured power cable
A power cable incorporating a metallic armour layer as part of its specified construction.
Steel Wire Armour (SWA)
A cable armour construction using steel wires. Suitability depends on the complete design and installation requirements.
Steel Tape Armour (STA)
A cable armour construction using steel tape as specified in the cable design.
Aluminium Wire Armour (AWA)
A non-magnetic armour option used in suitable cable designs where magnetic effects need to be considered.
Low-Voltage (LV) Cable
A power cable designed for a specified low-voltage system, with its rated voltage and construction defined by the applicable documentation.
Medium-Voltage (MV) Cable
A power cable designed for a specified medium-voltage application, with insulation, screening, and other construction details determined by the applicable design and standard.
Factory Acceptance Testing (FAT)
Testing and inspection carried out at the factory according to an agreed procedure, scope, and acceptance criteria.
Tell Huanghe Cable about your LV or MV power cable project. Share your specification, quantity, or cable schedule, and let us review the requirements with you.
Email: sales@huanghecables.com

Please contact us for a free quotation by the below form. We promise the quickest response within 12 hours.