Updated 2026/10/30 · Edited by Huanghe Cable Technical Team · Reading time: 10–13 minutes
Key Takeaways
When looking for a trusted H07V-K wire manufacturer, procurement teams require a comprehensive evaluation beyond nominal cross-sectional areas and unit pricing. Conductor construction, insulation integrity, rated voltage, governing standards, and packaging parameters must be rigorously aligned with operational project specifications.
H07V-K wire is globally recognized as a harmonized European flexible PVC-insulated copper conductor. In international procurement, buyers often compare it with BVR wire from China or VCm cable from the Vietnamese market. Although these alternatives serve comparable internal wiring functions, differing regional designations do not guarantee identical conductor classes, insulation profiles, or standard compliance.
This guide compares the main specifications, explains the differences between H07V-K, BVR, VCm, and solid-core PVC wire, and outlines what buyers should provide when requesting a quotation from a manufacturer.
Table 1. What each part of the H07V-K designation means
| Position | Character | Meaning |
|---|---|---|
| 1 | H | Harmonised — the type is defined by the CENELEC harmonisation document, not by a single national body. This is why the same wire is sold as 6491X in the UK and as H07V-K across the EU. |
| 2–3 | 07 | Rated voltage class: 450/750 V. The digit is the U0 value divided by 100, so 05 means 300/500 V. This single digit is the most common source of mistaken substitution between H05V-K and H07V-K. |
| 4 | V | Insulation compound: PVC (thermoplastic polyvinyl chloride). Under EN 50525-2-31 the compound is type TI1, specified in EN 50363-3. |
| 5 | K | Conductor class: Class 5 fine-stranded per IEC 60228. The alternatives are U (Class 1 solid) and R (Class 2 stranded). K is the only suffix that specifies flexibility, and it is the suffix most often dropped by suppliers quoting a “similar” wire. |
Source note: designation structure per CENELEC HD 21.3 S3 and EN 50525-2-31. Conductor class definitions per IEC 60228.
H07V-K is generally used to describe a single-core flexible copper wire with PVC insulation. Its stranded conductor offers greater flexibility than a solid conductor, making it suitable for wiring applications where the conductor must be routed through equipment, cabinets, or wiring ducts.
The following table summarizes the typical H07V-K specification basis and Huanghe Cable’s corresponding flexible-wire and BVR product ranges. H07V-K aligns with harmonized European specifications, while Huanghe’s BVR complies with Chinese national standards (GB/T 5023.3 / IEC 60227-3). Let our engineering team help verify the exact compliance matching your destination market.
Table 2. H07V-K vs. Huanghe BVR Wire Specification Comparison
Swipe horizontally to view all table columns on mobile.
| Parameter | H07V-K | Huanghe BVR Wire |
|---|---|---|
| Conductor | Flexible stranded copper conductor | Flexible copper-core conductor |
| Insulation | PVC | PVC |
| Typical rated voltage | 450/750V | 450/750V |
| Customized voltage | 0.6/1kV may be requested; design and standard require confirmation | 0.6/1kV can be requested for customization, subject to technical confirmation |
| Cross-sectional area | Production range: 0.75–240 mm²; tailored to match exact H07V-K standards upon technical review. | 0.5–400 mm² |
| Applicable standard | Typically specified against the applicable harmonized product standard, such as EN 50525-2-31; confirm the exact standard required | GB/T 5023.3 (equivalent to IEC 60227-3) for fixed wiring non-sheathed PVC cable; confirm the edition on the datasheet. |
| Product designation | Harmonized European wire designation | Chinese wire designation |
Standards note: EN 50525-2-31 is a relevant reference for certain PVC-insulated single-core non-sheathed cables, but the applicable edition and scope must be checked against the specific H07V-K design. Both H07V-K and BVR rely on IEC 60228 Class 5 fine-stranded copper conductors for flexibility; however, IEC 60228 is strictly a conductor specification standard and must be complemented by the appropriate complete product standard. The relevant GB/T product standard should be identified for BVR.
Voltage note: 450/750V is the typical rating used in this guide. If a project requires 0.6/1kV, specify this in the RFQ before production. The manufacturer must verify if a heavier insulation wall and modified construction are required to meet the higher voltage rating, and confirm the applicable standards and testing scope. If your project specification mandates a 0.6/1kV insulation wall for single-core flexible cables, simply note it in your RFQ. Our technical team will review your drawing and adjust the insulation thickness and test voltage accordingly.
For small sections below 1.5 mm², some manufacturers offer a 300/500V equivalent (often designated H05V-K or 2491X). If the project requires 450/750V across all sizes, state this explicitly in the RFQ and confirm the declared voltage for each size on the datasheet.
Buyers commonly search for specific sizes such as 0.75 mm², 1.0 mm², 1.5 mm², 2.5 mm², 4 mm², and 6 mm². Larger cross-sections may also be required for particular equipment or wiring specifications.
Huanghe’s flexible-wire production range spans from 0.75 mm² to 240 mm². For specific industrial specifications or large-scale project requirements, our sales team will gladly verify stock availability and tailored production schedules. For BVR, Huanghe’s stated cross-sectional area range is 0.5–400 mm².
Table 3. H07V-K Typical Conductor, Insulation and Electrical Parameters
Swipe horizontally to view all table columns on mobile.
| Size (mm²) | Min. strands / max. strand dia. | Nominal insulation (mm) | Max. DC resistance at 20 °C (Ω/km) | Approx. OD (mm) |
|---|---|---|---|---|
| 0.5 | 16 / 0.21 | 0.6 | 39.0 | 2.2 |
| 0.75 | 24 / 0.21 | 0.6 | 26.0 | 2.4 |
| 1.0 | 32 / 0.21 | 0.6 | 19.5 | 2.6 |
| 1.5 | 30 / 0.26 | 0.7 | 13.3 | 3.0 |
| 2.5 | 50 / 0.26 | 0.7 | 7.98 | 3.6 |
| 4 | 56 / 0.31 | 0.8 | 4.95 | 4.2 |
| 6 | 84 / 0.31 | 0.8 | 3.30 | 4.9 |
| 10 | 80 / 0.41 | 1.0 | 1.91 | 6.5 |
| 16 | 128 / 0.41 | 1.0 | 1.21 | 7.8 |
| 25 | 200 / 0.41 | 1.2 | 0.780 | 9.6 |
| 35 | 280 / 0.41 | 1.2 | 0.554 | 11.0 |
| 50 | 400 / 0.41 | 1.4 | 0.386 | 13.0 |
| 70 | 356 / 0.51 | 1.4 | 0.272 | 15.2 |
| 95 | 485 / 0.51 | 1.6 | 0.206 | 17.6 |
| 120 | 614 / 0.51 | 1.6 | 0.161 | 19.6 |
| 150 | 765 / 0.51 | 1.8 | 0.129 | 21.9 |
| 185 | 944 / 0.51 | 2.0 | 0.106 | 24.4 |
| 240 | 1226 / 0.51 | 2.2 | 0.0801 | 27.9 |
Source note: strand counts and 20 °C resistance limits are the Class 5 values of IEC 60228. Nominal insulation thickness follows EN 50525-2-31 / IEC 60227-3. Approximate outer diameters are for planning only — they vary with the insulation compound, the extrusion tooling and the measured-over-conductor method, so treat the manufacturer’s datasheet as the governing figure.
Table 4. Procurement and Application Guide by Wire Size Tier
Swipe horizontally to view all table columns on mobile.
| Cross-Section Tier | Typical Application Focus | Key Procurement Data to Specify |
|---|---|---|
| Small Sizes (0.5 – 1.0 mm²) | Control panels, sensor wiring, internal electronic assemblies | Confirm exact voltage class (300/500V vs 450/750V) and insulation color |
| Standard Sizes (1.5 – 6.0 mm²) | General building wiring, switchgear, industrial control boxes | Specify harmonized standard (H07V-K) or national equivalent (BVR) |
| Medium Sizes (10 – 35 mm²) | Power distribution panels, heavy industrial machinery connections | Verify Class 5 flexible conductor construction and DC resistance limits |
| Large Sizes (50 – 240 mm² & BVR up to 400 mm²) | Main power feeds, high-capacity industrial equipment | Confirm manufacturing availability, packaging (drums), and test certificates |
These sizes are examples to support procurement planning, not a guarantee of stock availability. When requesting a large-section wire, provide the required conductor class, rated voltage, product standard, and any project-specific drawing or datasheet.
Avoid project delays by verifying technical standards, voltage ratings, and compliance documents directly with our engineering and foreign trade team. Get a matched bulk quotation within 12 hours.
Similar PVC-insulated wires can be described differently in different markets. The safest approach is to identify the required designation first and then compare the actual construction and compliance requirements.
Table 5. Comparison and Verification Guide for Flexible Wire Designations
Swipe horizontally to view all table columns on mobile.
| Designation | General description | Key checks | Huanghe product reference |
|---|---|---|---|
| H07V-K | Flexible stranded copper conductor with PVC insulation | Harmonized designation, product standard, conductor class, and 450/750V rating | Provide the exact H07V-K specification for technical review |
| BVR | Chinese designation for flexible copper-core PVC-insulated wire | Applicable GB/T requirements, size, conductor construction, and voltage | 0.5–400 mm²; typically 450/750V; 0.6/1kV can be requested for customization. See Huanghe BVR wire (0.5-400 mm²). |
| VCm | PVC-insulated flexible wire designation typically encountered in Vietnamese local catalogues | TCVN 6610-3 (equivalent to IEC 60227-3), rated voltage, and insulation wall thickness. | Provide the required local catalogue reference or technical datasheet |
| Solid-core PVC wire | PVC-insulated wire with a solid conductor | Conductor type, installation method, voltage rating, and standard | See Single Core PVC Wire Cable. |
Not automatically. These designations follow different market conventions and may be associated with different product standards. Similar intended applications do not prove that conductor class, insulation dimensions, rated voltage, or conformity status are identical.
When European projects specify H07V-K, substituting with BVR or VCm requires careful cross-checking of insulation thickness and conductor class. Our technical consultants can provide side-by-side comparison datasheets to ensure smooth project approval. If equivalent substitutions are permitted, ensure the manufacturer provides comprehensive technical documentation outlining any variances before formal approval.
Insulation colour is another field that does not translate automatically between designations. H07V-K typically offers black, brown, grey, blue, yellow-green, red and white as standard, with other colours on request. BVR in the Chinese market commonly uses red, yellow, blue, green, black, white and yellow-green, and VCm catalogues list a similar but not identical set. State the required colour scheme in the RFQ rather than assuming one designation’s convention applies to another.
The product standard should be identified explicitly in the purchase specification. H07V-K is commonly associated with harmonized European wire requirements. EN 50525-2-31 may be relevant to certain PVC-insulated single-core non-sheathed cables, while IEC 60227-3 may be relevant to particular PVC-insulated wire types. The applicable standard depends on the exact design and market requirement.
For BVR specified for the Chinese market, the relevant product standard is GB/T 5023.3, which is equivalent to IEC 60227-3. Confirm the edition and scope on the manufacturer’s datasheet for the exact size and construction. H07V-K and Huanghe’s BVR utilize IEC 60228 Class 5 stranded copper conductors for high flexibility, though IEC 60228 remains a dedicated conductor standard and does not replace complete product safety and performance standards.
Before placing an order, confirm the following:
A certificate or report should not be assumed to cover every product in a manufacturer’s catalogue. If the project requires compliance with a particular standard, ask the supplier to identify the relevant document and its scope.
Flexible single-core PVC wire is used where the specified conductor construction and insulation are suitable for the installation. Typical contexts may include:
Operational suitability is strictly contingent upon installation methodologies, ambient thermal conditions, ampacity requirements, mechanical stress exposure, and local electrical codes. It must be noted that standard PVC insulation does not render a wire suitable for direct burial, unshielded outdoor exposure, or aggressive industrial environments.
If a project specifies a solid conductor, compare the requirement with a suitable solid-core PVC wire rather than selecting a flexible wire solely because its cross-sectional area is the same. See Huanghe’s Single Core PVC Wire Cable product page for a related product reference.
For bulk purchasing, a useful price comparison starts with a like-for-like specification. Two quotations should not be compared solely by price per metre if their conductor construction, rated voltage, product standard, insulation, packaging, or inspection requirements differ.
Table 6. Key Quotation Items and Procurement Information Guide
Swipe horizontally to view all table columns on mobile.
| Quotation item | Why it matters | Information to provide |
|---|---|---|
| Conductor size and construction | Material consumption and conductor requirements affect the specification and cost | Cross-sectional area, conductor class, and material |
| Rated voltage | Different voltage ratings may require different designs and compliance checks | 450/750V or requested 0.6/1kV |
| Product standard | Design, testing, and documentation must match the requirement | Standard number and project-specific requirements |
| Insulation and colour | Material requirements, colour, and dimensions can differ | PVC requirements and colour schedule |
| Quantity and packaging | Order volume and packing format affect production and logistics planning | Metres per size, coil/reel length, and packing |
| Testing and inspection | Required inspection and documentation must be included in the quotation scope | Test reports, inspection arrangements, and document list |
| Delivery terms | Freight, destination, and trade terms affect landed cost | Destination port/address and requested Incoterm |
For an accurate quotation, send the complete specification and quantity instead of asking for a price for “PVC wire” alone. If alternatives are acceptable, identify which requirements are mandatory and which may be proposed by the manufacturer.
Huanghe Cable is a cable manufacturer established in 1980, with a manufacturing background developed over several decades. The company’s published profile lists more than 60 production lines and 45 testing machines, supporting its range of power cables and electrical wires.
1980
Year established
60+
Production lines listed in the company profile
45
Testing machines listed in the company profile
Huanghe’s product portfolio includes LV and MV XLPE power cables, copper and aluminium conductors, armoured and unarmoured cables, control cables, photovoltaic cables, overhead conductors, building wires, and flexible PVC-insulated wire products. The factory’s production capabilities cover multiple cable constructions and project-specific requirements.
Testing requirements should be matched to the product design and purchase specification. For wire and cable orders, buyers can identify the required inspection scope, routine tests, test records, and any third-party inspection requirements in the RFQ. Where SGS inspection or reporting is requested and available for the order, the scope and deliverables should be agreed in advance.
Any certificate or test report should be checked against the actual product and its scope. A factory inspection report is not the same as product certification, and documentation for one model should not be assumed to cover every wire or cable manufactured by the company.
Huanghe’s published company information identifies markets including Southeast Asia, Central Asia, Africa, and South America. For export orders, procurement teams should confirm packaging, marking, reel or coil lengths, shipping documents, destination requirements, and delivery terms before production begins.
For H07V-K inquiries, buyers should provide the required harmonized designation and standard so Huanghe’s technical team can assess whether the requested construction can be supplied. For BVR, Huanghe’s stated range is 0.5–400 mm² at a typical rated voltage of 450/750V, with 0.6/1kV available for customization subject to technical confirmation.
Relevant product pages: BVR / Earth Cable and Single Core PVC Wire Cable.
Use the following checklist when preparing an inquiry. The more complete the information, the easier it is for a manufacturer to confirm the correct product and prepare a comparable quotation.
Subject: RFQ – Flexible PVC Wire
Product designation: H07V-K / BVR / VCm / specified equivalent
Conductor: Copper; specify required conductor class
Cross-sectional areas: List each required size
Rated voltage: 450/750V or requested 0.6/1kV
Insulation: PVC
Applicable standard: Insert the project requirement
Colour: Required colour per size. Standard ranges differ: H07V-K typically offers black, brown, grey, blue, yellow-green, red and white; BVR commonly adds green and uses yellow-green as the option; VCm catalogues list red, yellow, blue, black, grey and yellow-green. Confirm the manufacturer’s actual range for the size being quoted.
Quantity: Metres per size
Packing: Coil/reel length and packaging requirements
Destination: Port or delivery address
Required documents: Certificates, test reports, or inspection records
Required delivery date: Insert date
If you are sourcing BVR or VCm rather than H07V-K, state the exact designation and attach the relevant technical data sheet where possible. If equivalent products are permitted, ask the supplier to identify the proposed differences in writing before order approval.
The typical rated voltage covered in this guide is 450/750V. If the project requires 0.6/1kV, state this in the RFQ and ask the manufacturer to confirm whether a suitable customized construction can be supplied under the required standard.
Huanghe’s stated BVR cross-sectional area range is 0.5–400 mm². The typical rated voltage is 450/750V; 0.6/1kV can be requested for customization, subject to confirmation of the product design, standard, and testing requirements. See the BVR / Earth Cable product page.
The corresponding flexible-wire production range is 0.75–240 mm². Availability under a particular H07V-K designation depends on the exact construction, rated voltage, and applicable standard and should be confirmed before ordering.
Not automatically. BVR is a Chinese wire designation, while H07V-K is associated with harmonized European wire designations. Their construction and compliance requirements must be compared against the relevant product specifications before one is accepted as an alternative to the other.
Do not assume that they are identical. VCm is encountered in Vietnamese-market catalogues, and its rated voltage and construction should be verified against the specific manufacturer’s datasheet and the required standard.
Yes, you can submit a request for a customized 0.6/1kV product. The manufacturer must confirm the design, applicable standard, insulation requirements, and testing scope. The 0.6/1kV rating should not be assumed to be interchangeable with a standard 450/750V product.
Provide the designation (H07V-K, BVR, or VCm), conductor material and class, cross-sectional area, rated voltage, applicable standard, insulation colour, quantity per size, packing, destination, and required documents. The checklist in Section 8 covers the full list; attach a datasheet or BOQ if available.
Looking for H07V-K, BVR, or a specified PVC-insulated wire for a project or distribution order? Send Huanghe Cable your required sizes, voltage rating, product standard, quantities, and delivery details. Our team can review the specification and confirm the suitable product scope before quotation.
For faster technical review, attach a datasheet or project specification if available.

Please contact us for a free quotation by the below form. We promise the quickest response within 12 hours.