0.6/1kV, 1.8/3kV Low Voltage LV XLPE Insulation Power Cable IEC60522-1, DIN VDE 0276-603 |
|||||
|
Cable Models |
Cable Construction |
Description |
NO. of Cores & Nominal Cross Section Area mm² |
||
|
YJV N2XY |
cu/xlpe/pvc cable |
copper conductor, xlpe insulation, pvc sheath cable |
1 core
3+1 core
0.5, 1.0, 1.5, 2.5,
4, 6, 10, 16, 25,
35, 50, 70, 95
120, 150, 185, 240
300, 400, 500,
630, 800mm² |
||
|
YJLV NA2XY |
al/xlpe/pvc cable |
aluminum conductor, xlpe insulation, pvc sheath cable |
|||
|
YJV22 N2XBY |
cu/xlpe/pvc/dsta/pvc cable |
copper conductor, xlpe insulation, pvc inner sheath, double steel tape armoured, pvc outer sheath cable |
|||
|
YJLV22 NA2XBY |
al/xlpe/pvc/dsta/pvc cable |
aluminum conductor, xlpe insulation, pvc inner sheath, double steel tape armoured, pvc outer sheath cable |
|||
|
YJV32 N2XRY |
cu/xlpe/pvc/swa/pvc cable |
copper conductor, xlpe insulation, pvc inner sheath, steel wire armoured, pvc outer sheath cable |
|||
|
YJLV32 NA2XRY |
al/xlpe/pvc/swa/pvc cable |
aluminum conductor, xlpe insulation, pvc inner sheath, steel wire armoured, pvc outer sheath cable |
|||
|
YJLY23 NA2XB2Y |
al/xlpe/pe/dsta/pe |
aluminum conductor, xlpe insulation, pe inner sheath, double steel tape armoured, pvc sheath cable |
|||
|
WDZ-YJY N2XH |
cu/xlpe/lszh (with Green/Yellow protective conductor) |
copper conductor, xlpe insulation, low some zero halogen (LSZH) sheath cable |
|||
|
WDZ-YJY N2XH-O |
cu/xlpe/lszh (without Green/Yellow protective conductor) |
copper conductor, xlpe insulation, low some zero halogen (LSZH) sheath cable |
|||
|
WDZ-YJY33 N2XRH |
cu/xlpe/lszh/swa/lszh |
copper conductor, xlpe insulation, low smoke zero halogen (LSZH) inner sheath, steel wire armoured, low smoke zero halogen (LSZH) outer sheath cable |
|||
|
WDZN-YJY N2XH FE 180 |
cu/mica/xlpe/lszh cable |
copper conductor, mica tape, xlpe insulation, low smoke zero halogen (LSZH) sheath, fire rated cable |
|||
|
WDZN-YJY33 N2XRH FE 180 |
cu/mica/xlpe/lszh/swa/lszh cable |
copper conductor, mica tape, xlpe insulation, low smoke zero halogen (LSZH) inner sheath, steel wire armoured, low smoke zero halogen (LSZH) outer sheath, fire rated cable |
|||
|
WDZN-YJY23 |
cu/mica/xlpe/lszh/dsta/lszh cable |
copper conductor, mica tape, xlpe insulation, low smoke zero halogen (LSZH) inner sheath, double steel tape armoured, low smoke zero halogen (LSZH) outer sheath, fire rated cable |
|||
|
NH-YJV |
cu/mica/xlpe/pvc cable |
copper conductor, mica tape, xlpe insulation, pvc sheath, fire rated cable |
|||
|
NH-YJV22 |
cu/mica/xlpe/pvc/dsta/pvc cable |
copper conductor, mica tape, xlpe insulation, pvc inner sheath, double steel tape armoured, pvc outer sheath, fire rated cable |
|||
|
Note: 💡 Don't see your specific project standard? We offer 100% full customization for any international specification. [Get Custom Spec & Pricing Now] |
|||||
|
3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV, 18/30kV, 26/35kV Medium Voltage MV XLPE Insulation Power Cable |
|||||
|
China Cable Models (GB) |
German Cable Models (DIN VDE) |
XLPE Insulation Cable Construction |
NO. of Cores & Nominal Cross Section Area |
||
|
MV Unarmoured Cables |
YJV
(copper wire + copper tape screen) |
N2XSY/NC2XSY
(single core) |
cu/xlpe/pvc
|
Conductor: copper
Conductor Screen: semi-conductive material
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive material
Screen: copper wires and tape
Outer Sheath: polyvinyl chloride (PVC) |
single core,
3 core
25, 35, 50, 70,
95, 120, 150,
185, 240, 300,
400, 500,
630mm² |
|
N2XSEY
(3 core, individually screened cores) |
|||||
|
YJLV
(copper wire + copper tape screen) |
NA2XSY
(single core) |
al/xlpe/pvc |
Conductor: Aluminum
Conductor Screen: semi-conductive material
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive material
Screen: copper wires and tape
Outer Sheath: polyvinyl chloride (PVC) |
||
|
NA2XSEY
(3 core, individually screened cores) |
|||||
|
YJY
(copper wire + copper tape screen) |
N2XS2Y (single core) |
cu/xlpe/pe |
Conductor: copper
Conductor Screen: semi-conductive material
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive material
Screen: copper wires and tape
Outer Sheath: polyethylene (PE) |
||
|
YJLY
(copper wire + copper tape screen) |
NA2XS2Y (single core) |
al/xlpe/pe |
Conductor: aluminum
Conductor Screen: semi-conductive material
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive material
Screen: copper wires and tape
Outer Sheath: polyethylene (PE) |
||
|
MV Armoured Cables
|
YJV62/YJLV62
(copper tape screen) |
N2XSB(AL)Y/
NA2XSB(AL)Y
(single core) |
cu(al)/xlpe/pvc/ata/pvc |
Conductor: copper (aluminum)
Conductor Screen: semi-conductive
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive
Screen: copper tape
Inner Sheath: polyvinyl chloride (PVC)
Armour: aluminum tape armour (ATA)
Outer Sheath: polyvinyl chloride (PVC) |
|
|
YJV72/YJLV72
(copper tape screen) |
N2XSR(AL)Y/
NA2XSR(AL)Y
(single core) |
cu(al)/xlpe/pvc/awa/pvc |
Conductor: copper (aluminum)
Conductor Screen: semi-conductive
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive
Screen: copper tape
Inner Sheath: polyvinyl chloride (PVC)
Armour: aluminum wire armour (AWA)
Outer Sheath: polyvinyl chloride (PVC) |
||
|
YJV22/YJLV22
(copper tape screen) |
N2XSBY/
NA2XSBY
(3 core) |
cu(al)/xlpe/pvc/dsta/pvc |
Conductor: copper (aluminum)
Conductor Screen: semi-conductive
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive
Screen: copper tape
Inner Sheath: polyvinyl chloride (PVC)
Armour: double steel tape armour (DSTA)
Outer Sheath: polyvinyl chloride (PVC) |
||
|
YJV32/YJLV32
(copper tape screen) |
N2XSRY/
NA2XSRY
(3 core) |
cu(al)/xlpe/pvc/swa/pvc |
Conductor: copper (aluminum)
Conductor Screen: semi-conductive
Insulation: cross-linked polyethylene (XLPE)
Insulation Screen: semi-conductive
Screen: copper tape
Inner Sheath: polyvinyl chloride (PVC)
Armour: steel wire armour (SWA)
Outer Sheath: polyvinyl chloride (PVC) |
||
|
Note: 💡 Don't see your specific project standard? We offer 100% full customization for any international specification. [Get Custom Spec & Pricing Now] |
|||||
| Rated Voltage: | 0.6/1kV, 1.8/3kV |
| Conductor: | aluminum or (tinned) copper (solid core class1, stranded core class2, flexible core class5 ) |
| Insulation: | Crosslinked Polyethylene (XLPE) PVC (optional) |
| Screen Layer (optional): | copper tape screen (cts) copper wire screen (cws) |
| Armour Type (optional): | steel tape armoured (dsta) steel wire armoured (swa) aluminum wire armoured (awa) |
| Outer Sheath: |
Polyvinyl Chloride (PVC) LSZH (optional) |
| Standards: | IEC/EN/BS/UL/CSA |
| Certifications: | CB Test Certificate/CCC/ISO 9001/ISO 14001 |
| Additional: | *FR, FRLS, LSZH, LSOH, LSHF, anti-termite cables are also available. *Our custom cable services are designed to meet your specific requirements. |

| Voltage: | 3.6kV ~35kV |
| Conductor: | Copper or Aluminum |
| Insulation: | Crosslinked Polyethylene (XLPE) |
| Screen Layer: | copper tape screen (cts) copper wire screen (cws) (optional) copper wire + copper tape Helically screen (optional) |
| Inner Sheath: |
Polyvinyl chloride (PVC) (optional) LSZH (optional) |
| Armour Type (optional): | steel tape armoured (dsta) steel wire armoured (swa) aluminum wire armoured (swa) aluminum tape armoured (ata) |
| Outer Sheath: |
Polyvinyl chloride (PVC) LSZH (optional) |
| Standards: | IEC/EN/BS/UL/CSA |
| Certifications: | CB Test Certificate/CCC/ISO 9001/ISO 14001 |
| Additional: | *FR, FRLS, LSZH, LSOH, LSHF, anti-termite cables are also available. *Our custom cable services are designed to meet your specific requirements |

Max Conductor Temp: 90℃
Short-Circuit Temp: 250℃
Benefit: Higher current-carrying capacity & overloaded safety.
Anti-Crush & Anti-Rodent:
Engineered for direct burial in harsh soil conditions.
Benefit: Zero maintenance costs.
LSZH & Flame Retardant:
Compliant with IEC 60332 standard for public buildings.
Benefit: Passes strict local fire audits easily.
|
Item |
Single Core |
Multi core |
||
|
Unarmored |
Armored |
Unarmored |
Armored |
|
|
Min.Bending Radius When installation |
20D |
15D |
15D |
12D |
|
Minimum bending radius of the cable near the connection box and terminal (bending should be carefully controlled, such as with a formed guide) |
15D |
12D |
12D |
10D |
|
* D means overall diameter of cables |
||||
|
Our History
|
Production Capabilities
|
Innovation & Customization
|

From high-purity materials to advanced manufacturing processes, we ensure every cable delivers top-tier performance and long-term reliability.
Our cables are flame retardant, eco-friendly, and fully compliant with international safety standards, ensuring peace of mind for your projects.
We provide tailored cable solutions to meet your exact specifications, ensuring optimal performance for your unique applications.
Certified by CCC, ISO, IEC etc. our products meet the highest global quality and safety benchmarks.
With 24/7 customer support, technical expertise, and a one-year warranty, we are committed to your success every step of the way.
As a leading global cable manufacturer, Huanghe Cable combines cutting-edge technology with decades of expertise to deliver high-performance cables and reliable service. Whether you're a distributor, trader, or contractor, we are your trusted partner for all your power transmission needs.
At Huanghe Cable, we don’t just sell cables, we deliver solutions that power your projects and drive your success. Contact us today to request a quote, discuss your requirements, or learn more about how we can support your business.

Please contact us for a free quotation by the below form. We promise the quickest response within 8 hours.